px3The complete device in the series.

It offers a 2-stage current capability filter (16A), 1000 VA transformer for amplifiers and 2 pieces 250 VA for source devices and preamplifiers.

PX Technical Data

The Transformers

We avoid by the use of an isolating transformer problems caused by frequently occurring changes in the current (mains frequency, sine function of the mains curve, frequency cuts, DC components, compensation currents etc.) For physical reasons, a separating transformer can only inductively convert sine-shaped alternating current and thus ensures a very clean supply of connected consuments.

The PX modules are equipped with toroidal isolation transformers with high load reserves, the PX CC modules include Double-C Core transformers with high Pulse Current delivery capability.